En Es
Categories

LEICA

Leica Biosystems develops and supplies cancer diagnostics devices and solutions in the areas of histology, digital pathology, and clinical micsorocopy, surgery and radiology. Its workflow solutions and automation enable clinicians to efficiently provide patients a diagnosis within 24-hours from biopsy.
Products Summary
Close

About LEICA

Leica Biosystems develops and supplies cancer diagnostics devices and solutions in the areas of histology, digital pathology, and clinical micsorocopy, surgery and radiology. Its workflow solutions and automation enable clinicians to efficiently provide patients a diagnosis within 24-hours from biopsy.
FaceBook Twitter Google+ Linked in
IHC and ISH Stainer

IHC and ISH Stainer

Model: BOND-III
Request Information

Description:

The BOND-III is a fully automated IHC and ISH stainer that is up to 50% faster than previous generation stainers and requires virtually no daily maintenance. It offers class-leading quality with superior Bond reagents and proven Covertile technology to ensure delivery of clear and accurate staining for unsurpassed diagnostic confidence.

Features Specifications

Features

When Delivering a Case to the Pathologist, it’s the Last Slide that MattersA complete case means that the last slide is as important as the first. BOND-III helps you deliver the entire case in the shortest amount of time while maintaining excellent standards in quality. Other systems prioritize individual slides at the expense of overall case completion, meaning it takes longer to finalize the last slide in the case. Request Information

Specifications

• Dimensions & Weight
• Dimensions (W x H x D): 790 mm x 1378 mm x 806 mm
(31.1 x 54.25 x 31.73 in)
• Weight (Dry): • 238 kg (525 lbs)
• Electrical
• Operating Voltage (older-model power supply; one fan in back cover): 103.4 V to 127.2 V (for nominal voltage 110 V to 120 V)
• Power Consumption: 1200 VA
• Operating Voltage (newer-model power supply; two fans in back cover): 90 V to 264 V (for nominal voltage 100 V to 240 V)
• Mains Frequency: 50/60 Hz
• Environmental (Unpacked Instruments)
• Maximum Operating Temperature: 35°C (95°F)
• Minimum Operating Temperature: 5°C (41°F)
• Temperature Required to meet Staining Performance Requirements: 18–26°C (64–79°F)
• Maximum Heating Energy Output: 1200W/1000W

• Operating Humidity (Non-Condensing): 30 to 80% RH
• Maximum Operating Altitude: 0 to 1600 m (5250 ft.) above sea level
• Sound Pressure Level Output (at 1 m): < 85 dBA maximum
< 65 dBA normal operation
• Operating
• Slide Capacity: 30
Finished trays (10 slides) may be replaced continuously
• Number of Reagent Containers: 36
• Reagent Container Capacity: 7 mL and 30 mL
• Titration Container Capacity: 6 mL
• Bulk Reagent Container Capacity: 2 L or 5 L
• Hazardous Waste Container Capacity: 5 L
• Standard Waste Container Capacity: 2 x 5 L
• Chemical Compatibility: All BOND Reagents
70% Alcohol Solution (for cleaning purposes)
• Temperature Indication: Defaults (these can be changed by service representatives): Warm: 35°C, Hot: 80°C
• Maximum permitted pressure for gas and liquid connections: 1.0 bar
• Microscope Slides
• Slide Width: 24.64–26.0 mm (0.97–1.02 in)
• Slide Length: 74.9–76.0 mm (2.95–2.99 in)
• Slide Thickness: 0.8–1.3 mm (0.03–0.05 in)
• Label Area Width: 24.64–26.0 mm (0.97–1.02 in)
• Label Area Length: 16.9–21.0 mm (0.67–0.83 in)
• Material: Glass, ISO 8037/1
• Transport and Storage (Packed Instruments)
• Storage Temperature: -20 to 55 °C (-4 to 131 °F)
• Storage Humidity (Non-Condensing): < 80% RH
• Shipping Methods: • Road and Air Freight Compatible Request Information