En Es
Categories

Siemens Healthineers - Laboratory Diagnostics

Provides advanced laboratory diagnostics solutions for the medical industry
Products Covid-19NewsSummary
Close

Covid-19 Siemens Healthineers - Laboratory Diagnostics

Clinical Laboratory

SARS-CoV-2 IgG Assays
Atellica IM and ADVIA Centaur SARS-CoV-2 IgG (sCOVG) Assays

Both the Atellica IM and the ADVIA Centaur SARS-CoV-2 IgG (sCOVG) assays measure IgG antibodies to SARS-CoV-2 in the blood to help clinicians assess the level of an individual's immune response over time. The assays produce results rapidly in as few as 25 minutes on the Atellica IM Analyzer and enable accurate antibody testing on a large scale for both reference laboratories and acute care settings.
More details

SARS-CoV-2 Assay
SARS-CoV-2 Total (COV2T) Assay

The SARS-CoV-2 Total (COV2T) Assay detects both IgM and longer-lasting IgG antibodies with high sensitivity of recent and prior infection using proven antibody-bridging assay architecture to avoid false-positive results. It produces results in as little as 10 minutes on the Atellica IM Analyzer with a capacity to process up to 440 assays per hour.
More details

Interleukin-6 (IL-6) Assay
ADVIA Centaur IL6 Assay

The ADVIA Centaur IL6 Assay measures the presence of Interleukin-6 (IL-6) which is an indicator of potential severe inflammatory response in patients with confirmed SARS-CoV-2 infection. The simple blood test measures IL-6 in human serum or plasma to aid in determining the risk for hospitalized of COVID-19 patients of needing intubation with mechanical ventilation, in conjunction with clinical findings and the results of other laboratory testing.
More details

SARS-CoV-2 Assay
FTD SARS-CoV-2 Assay

The FTD SARS-CoV-2 Assay for the specific detection of the novel coronavirus causing COVID-19 is designed for high sensitivity, specificity, and inclusivity. It covers highly conserved regions within ORF1ab and N gene, and uses the same assay setup protocol and thermal-cycling profile as all FTD respiratory disease kits.
More details

SARS-CoV-2 Assay
SARS-CoV-2 Total (COV2T) Assay

The SARS-CoV-2 Total (COV2T) Assay detects both IgM and longer-lasting IgG antibodies with high sensitivity of recent and prior infection, allowing for identification of patients who have developed an adaptive immune response, which indicates recent infection or prior exposure. The assay uses a proven antibody-bridging assay architecture, which involves binding of a single SARS-CoV-2 antibody to two identical SARS-CoV-2 antigens, helping to avoid false-positive results.
More details
Close

News of Siemens Healthineers - Laboratory Diagnostics

Siemens and Sysmex Extend Agreement to Provide One of the Largest Portfolios of Hemostasis Testing Systems and Reagents

05 Feb 2021
Siemens and Sysmex Extend Agreement to Provide One of the Largest Portfolios of Hemostasis Testing Systems and Reagents
Siemens Healthineers (Erlangen, Germany) and Sysmex Corporation (Kobe, Japan) have renewed their long-standing global supply, distributorship, sales and service agreement for a broad portfolio of hemostasis products, including a multi-year extension.
Read More
Close

About Siemens Healthineers - Laboratory Diagnostics

Provides advanced laboratory diagnostics solutions for the medical industry
FaceBook Twitter Google+ Linked in
Immunoassay System

Immunoassay System

Model: ADVIA Centaur XPT
Request Information

Description:

The ADVIA Centaur XPT Immunoassay System delivers the results that clinicians depend upon for accurate diagnoses and better patient care—and does so predictably and consistently. Designed with one of the most advanced software packages on the market, it is among the highest-throughput systems available, leading to greater laboratory productivity to stay ahead of increasing workload demands.

Features Specifications

Features

SIMPLIFIED, CONTINUOUS OPERATION
• Intuitive, icon-driven user interface for simplified training and operation
• On-the-fly loading and unloading of samples, reagents, and supplies
• 2D bar-code scanner uploads test definitions with one easy scan, saving valuable time
• Automated daily maintenance and no monthly cleaning procedures
• No daily startup procedure
• Status light displays system alerts visible from anywhere in the laboratory

ACCURATE, TIMELY RESULTS
• Comprehensive menu supports over 70 tests
• Versatile, advanced AE technology, with over 40 active patents, enables continual introduction of new and innovative assays
• Up to 240 tests per hour for fast turnaround, even during peak workload times
• STAT port allows priority sampling at any time, even when connected to automation
• Highly stable, ready-to-use reagents are used on all ADVIA Centaur systems
• Disposable sample tips ensure no sample-to-sample carryover
• Automated clot management virtually eliminates operator intervention
• SMART algorithm software automates repeat and confirmatory testing of reactive samples

POWERFUL, SEAMLESS CONNECTIVITY
• Designed for automation; requires no additional robotics
• Point-in-space technology enables direct-from-track sampling
• STAT samples can be front-loaded at any time for immediate sampling, driving rapid turnaround time (TAT)
• Direct connectivity to Siemens Automation Solutions, the CentraLink™ Data Management System, and Siemens Remote Service (SRS) , enabling laboratories to adapt and grow as their workloads demand Request Information

Specifications

• System Description: Random-access immunoassay system
• Test Throughput: Up to 240 tests per hour
• Time to First Result: 18 minutes; results every 15 seconds thereafter, assay dependent
• Assays Onboard: 30 assays
• Disease-State Assay Groups: Allergy, Anemia/Iron Metabolism, Bone Metabolism, Cardiac, Diabetes, Hepatitis, Immunosuppressant Drugs, Metabolic, Oncology, Reproductive Endocrinology, Special ID, Therapeutic Drug Monitoring (TDM), Thyroid, ToRCH
• Continuous Operation: Loading/unloading of samples and consumables at any time without interrupting system operation. Includes sample racks, STATs, reagent packs, ancillary reagent packs, reaction cuvettes, sample pipette tips, calibrators, controls, wash fluids, water, and waste.
• Sample Tubes: 3 mL, 5 mL, 7 mL, and 10 mL tubes; 1 mL and 2 mL sample cups; microcontainer tubes
• Sample Input: Universal 5-position rack holds multiple tube types; 180 samples fully loaded; no-pause loading and unloading
• Validated Sample Types: Serum, plasma, urine (assay-dependent)
• Sample Volume per Test: 10–200 μL, assay-dependent
• Sample Integrity Control: Pressure transducer technology with clot detection, flagging, and management; short-sample detection
• STAT Handling: Dedicated STAT port accepts samples any time; STAT samples are processed with priority
• Auto-repeat: User-definable
• Sample Dilution: Automatic dilution varies by assay, up to 1:2500
• Auto-reflex Testing: Automatic ability to perform additional tests based on results of first test
• Sample Pipette Tips: 840 disposable sample tip capacity
• Sample Carryover Prevention: Disposable pipette tips ensure zero sample carryover
• Sample Bar Codes: Up to 20 digits; Interleaved 2 of 5; Code 39, Code 128, Codabar; A, B, and special characters (.-+/*$%)
• Reaction Cuvettes: Capacity of 1000 optical-grade plastic cuvettes
• Reaction Bath: Air bath, 37°C
• Assay Result Calculations: SMART algorithm software repeats and confirms reactive testing; results available as completed
• Assay Technology: Chemiluminescence using Advanced Acridinium Ester
• Reagent Tray: 30-position reagent tray refrigerated between 4 and 10°C (39–50°F)
• Reagent Capacity Onboard: 30 assays
• Reagent Containers: ADVIA Centaur® ReadyPack® (various pack sizes available)
• Reagent Integrity Control: Bar-code reagent identification, automatic inventory tracking and flagging, calibration valid tracking and flagging, reagent onboard stability tracking and flagging, reagent expired/reagent low flagging
• Onboard Stability: 28 days (average)
• Reagent Mixing: ADVIA Centaur ReadyPacks automatically rocked onboard
• Ancillary Reagents: 25-position ancillary reagent tray cooled 4–8°C (39–46°F)
• Auto-calibration/Auto-QC: Available automatic QC ordering by test, control, date, and time
• QC Data: Advanced QC package includes Levey-Jennings plots and Westgard rules
• Monitor: 22-inch diagonal high-resolution LCD touchscreen with adjustable height
• Operating System: Microsoft® Windows® 7
• System Documentation: Operator manual, quickstart guide, and context-sensitive online help
• Data Storage: 1,000,000 test/QC results; 500,000 can be historical; can archive to removable media
• Onboard Maintenance Logs: Yes
• Host Interface: RS232C bidirectional and host query; Ethernet connection available
• Host Query: Yes
• Remote Access & Service: 1000Base-T Ethernet port for remote access and modem for Siemens Remote Service
• Removable Media: CD, DVD, or USB
• Power Requirements: 200-240 V at 50/60 Hz; 1.2 kW maximum
• Maximum Water Consumption: 2.5 liters (0.6 gallons) per hour
• Drain Requirements: Minimum of 2.5 liters (0.6 gallons) per hour
• Dimensions: With monitor: 167 (h) x 196 (w) x 104 (d) cm; 66 (h) x 77 (w) x 41 (d) in.; Without monitor: 133 (h) x 196 (w) x 104 (d) cm; 52 (h) x 77 (w) x 41 (d) in.
• Weight: 585 kg (1289 lb)
• Compliance: Complies with international environmental, health, and safety standards
• Noise Emission: 65 dB maximum
• Processing Heat Output: 5100 BTU/hour
• Ambient Temperature: 18–30°C (64–86°F)
• Ambient Humidity: 20–80% noncondensing
• Floor Load-Bearing Requirement: 412 kg/m2 (84 lb/ft2) Request Information

Send A Message To This Supplier

* Required Information
* Email
To
Siemens Healthineers - Laboratory Diagnostics (Immunoassay System)
* Message

Copyright © 2000-2021 TradeMed.com. All rights reserved. | Terms And Conditions